Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. Now remove the terminal cover on the timer. I have a inground pool with T10003RT4 control panel. How about the GFCI outlet TEST button, is it tripped? Now try to jiggle it on and off. Or the switch can suffer wear over many years, and might not make solid contact. Are the trippers slid all the way onto the dial fully? Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. "keywords": "",
I believe its the manual on/off switch that is the problem. Could be small bugs, or dirt, or both causing the problem. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? Timer must be reset for current time after power outage. Pool pump comes on fine with the on dog, but wont turn off. I bought a new motor for mine after 20 years and learned about this the hard way. it could also be a failing breaker, but that would be a last resort. Did I wire it incorrectly or did I just get a bad timer? Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Is this a bad timer mechanism or loose wire? Make sure the middle time pointer is tight. However the new breaker is in a constantly tripped position. March 16, 2022 by WildRiverCountry. The same happens prior to the timer reaching the off tripper. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
They should be straight, if not, replace them. There is a switch control panel and replaced the 20amps DP switch as well. If the pump doesnt come on, follow the steps below. Below is a breakdown of how to wire different Intermatic timer models. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Open following links to identify timer and then add a comment. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. do i need to do something different? "width": "611",
Hi, hope you are doing well. The tripper will not move. I am having the same problem. Is that a faulty motor? If you cant, is the manual switch stuck or jammed? DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . There are many reasons why your pool timer may not be working. Simply screw it back into place until its snug. Read full answer 2/14/2023 3:20:07 AM If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. At some time the timer was disconnected and the pump wired direct to the breakers. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 OPEN TODAY, 12PM TO 3PM. You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. I had the exact same thing happen recently. Turn on / off manually work fine, but The clock gears still not moving. Sometimes old power wires split or short-out. How can it keep time if lever is in off position (manual lever). Move the start and stop pins to appropriate times for swimming pool filter operation. I flicked the switch between on and off and it will not shut off. My pool pump and skimmer are on two different motors. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Keeping a pool operational is expensive enough anyway, so every saving you can make helps. What is the problem? Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). any suggestions about how i might avoid another situation like the above would be appreciated. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. You will first want to look at the pool timer and see if you have two timer pins. Inside, the 1 gear on the right side can be removed to access a metal bar. Turn in either direction and align the exact time-of-day on . Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). That was probably what burned the plug. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A Still no luck. If all looks well, and the gears are still not turning, you may need to replace the mechanism. Voltage is 243, frequency is 60hz. Any thoughts before I run out to replace it? You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. The gears in mechanical timers can get damaged. Is the ON tripper all the way pushed onto the dial? Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. It is still moving and it will trip off but not on. However, after several hours, maybe overnight, the associated breaker will trip. One morning I noticed my pool didnt automatically turn off. No luck. i have an oval pool that is closed for the winter but there ha been a problem. we purchased the house 5 years ago so not sure how old the timer is? I have Model T40004RTe. Dead as a door nail. A recent power outage will cause the timer to stop working. Is the timer repairable, or should I just install a new one? If you are not sure if your timer is working or not you will first need to know if its even operational. It worked for a day but the day after it didnt work. Align the bar with the current time and push it back into place. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . The most common pool timer used for inground pool pumps is the Intermatic time clock. Hi, new timer out of the box, 200V. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. Give it a little squirt of WD-40 or similar lubricant. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. You need extreme care in this next step. Dont know what the issue is. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. I replaced the fuse(BUSS 300v GLR 3) as well. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. I have the PF1202T timer on my pool. My time clock has an ant infestation! I just replaced my T101 timer 2 years ago. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. My pool timer is in the off position and it is still running. Hello. Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. This is hard to check if you are not qualified. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. If your pool pump timer is beyond repair, call a professional to replace it. GFCI breakers trip at a very low threshold, doesnt take much. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. P.S. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. Is it Necessary? Do you have an answer to why my pump wont turn off or on? Hi Rich, is one of those wires (white?) "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Everythings OK now, unit works just fine. Replace them if they appear to be bent. Any help is greatly appreciated. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. Replaced complete new timer assuming 5 years perfect service probably wore it out. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. Thanks again for your help. And when switched on, power to the load terminals? Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. I bought a new timer and replace the T104 timer clock. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. HI Jeff, do you have power outages sometimes? The timer not working is for the pump. The position of the metal bar forces the gear next to it to turn one way or another. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. But of the timer itself is bad you will need a licensed electrician to change the timer for you. I think I have found it. You off course will want to adjust one time pin at a time. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. It is an ON tripper right? I had to order new trippers as mine have been straightened too many times. T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! What was the fix?? Switch the breaker off at the power board. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. #9. Or is there anything else I can check? Electrical Monke Aug 25, 2021 #22 It's broken. However, the timer will stop around 10pm everyday and will not continue moving forward again. Should it still not work, I suspect a motor failure for the clock. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. Is this broken? Does this mean I need a new T104, or is there a replacement manual on/off switch? I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. Some of the replacement motors make it past quality control with the incorrect gear setup. 1. Does this give you a better idea of the problem? The problem is the 'off' tripper. Replace a new T104. I noticed that they had stopped. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! 2,767 Sq. If you cant see an issue with the gears, then it could be the timer motor. Turn the metal bar until it contacts one of two plastic side tabs. Then remove the mechanism by pressing the clip at the top of the timer box. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. Second thing to check is the dial bent or warped, in that area where the on tripper is? Move the switch and see that they separate when off, and come together when on. There is a second switch between the breaker and the timer. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Refer to the wiring diagram on the timer door for more information. 3 Baths. You should always be able to switch your pump on and off manually at the timer. This will disengage the dial and allow you to spin it in either direction. Any guidance on how to fix this? There could also be other mechanical reasons for this happening, such as a disconnect in the switch. "url": "https://blog.intheswim.com/"
the trippers are even slightly damaged the timer won't work correctly. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. I took the electrical box cover off and check the breaker connections. Sometimes those are looped back to the control box. Found the answer. As an Amazon Associate we earn from qualifying purchases. (For outside light timer) The one before was original to the house & I had no trouble. Yes, likely a short to ground. You can replace the entire mechanism or the gears. The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. If it doesnt, there could be an issue with the clock face or gears. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. View more property details, sales history and Zestimate data on Zillow. I made sure the trippers were fully inserted and tight. Set the current time to the center time pointer, pointing downward at 6 oclock. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. Or there could be a bad relay in the control panel, if you have ice cube style relays. Hi, Davy, seeing lots of complaints here. Timer not tripping pump on. Jump to the troubleshooting steps below to fix the issue. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back.